User Manual

P B L Tunnels Loc 2 Units 1 & 2 + 800MHz BDA
Maintenance Handbook
H/book Number:-60-056100HBKM
Issue No:-1
Date:-13/02/2003
Page:-67 of 67
5.2 Location 2, Unit 2 (60-056102)
5.2.1 Two Section Notch Filter (02-010401)
5.2.1.1 Description
Fitted in Unit 2 after the amplification stages is a 2 element notch filter (one in downlink,
one in uplink), which is designed to reject the uplink frequencies in the downlink path and
vice-versa. The notch filter is not required for Unit One as the rejection from the two
series bandpass filters as apposed to one, is sufficient to meet the specification.
5.2.1.2 Technical Specification
Response type: Chebyshev
Frequency range:
485-486MHz
Bandwidth:
1MHz (tuned to spec.)
No. of sections:
2
Insertion loss:
dB
VSWR:
Better than 1.2:1
Connectors:
SMA
Power Handling:
100W maximum
operate:
-20°C to +55°C
Temperature range:
store:
-40°C to +70°C
Weight:
3 kg
Size:
384 x 82.5 x 56.4mm