User Manual
Table Of Contents
- 1 Introduction
- 2 Antenna Requirements
- 3 Installing the Repeater
- 4 Initial Setup and Commissioning
- 5 Administration
- 6 Maintenance and Troubleshooting
- Appendix A: Specifications
Axell BSR 3308-PS NFPA
Product Description and User’s Manual
© Axell Wireless Ltd Doc PN 4000004131 Rev. 2.7 39
4.6.3 Configuring SNMP Trap Destinations
You may configure traps to be sent to five destination addresses each time a fault is triggered. The
traps are sent at the defined heartbeat frequency.
To set SNMP Trap Destination parameters
1. In the Use Destination field, select the SNMP option
2. For each destination:
• Enter the IP Address (where the IP addresses should be in the same
subnet as the repeater).
• Define the Community names (default = public) of the computers to which
traps will be sent.
3. In the SNMP Trap Configuration area, in the Heartbeat Period field, define the
frequency (in minutes) at which traps will be sent.
NOTE: It is recommended to maintain the Enterprise ID as Axell.
4. Click Send.
4.7 What Next?
You have now completed the setup procedure. You may define Users according to the
following chapters.
Select SNMP option from
drop-down list
Define up to five SNMP
destination addresses