3.8 Antenna Connections
CAUTION!
Do not connect the antenna cables to the Repeater before verifying the installation parameters.
DO NOT POWER-UP the Repeater without either the antennas being connected or the antenna
connections terminated with dummy loads.
To connect the antennas to the Repeater
NOTE: If the coaxial cables are NOT weather-resistant type, wrap the exterior coaxial cables with
insulation and holding tape (Type 3M Rubber splicing tape) for environmental protection and to
ensure longer lifetime.
1. Install the antenna cables along their path to the Repeater, and connect them to the
Antennas.
NOTE: Be sure to use low loss cables.
2. Connect the Donor antenna to the Repeater BASE port. (Donor antenna
specifications and installation criteria are described in Chapter
2).
3. Connect the Service antenna to the Repeater MOBILE port. (Mobile antenna
specifications and installation criteria are described in Chapter
2).
4. Verify all RF connectors are tightened and the cables and antennas are secured.
3.9 Powering Up the BSR 3308 Repeater
Warning: Electrical Shock
This equipment must be installed indoors only. . To prevent electrical shock when installing or
modifying the system power wiring, disconnect the wiring at the power source before working with un-
insulated wires or terminals.
3.9.1 Non-NFPA AC Model - Power Connection
• Connect the cable from the AC/DC converter to the front panel DC Power port
and connect the AC/DC converter power cable to the AC outlet.
DC Input connection from
system AC/DC Converter