1.6 Interfaces
The following figure shows the interfaces on the BSR Repeater.
NOTE: The interfaces described in this section are the same for all BSR 3308 models.
Figure 1-2. BSR 3308 BSR PS NFPA Front Panel Interfaces
The following table provides a description of the front panel ports and connections.
Port
Description
Base Connection to Base side (donor) antenna
Mobile Connection to mobile side antenna
Ethernet Ethernet connection for local setup and remote management.
Dry contact NFPA
alarms
See section
3.10 for description of alarm connections.
DC Power DC models – ±48VDC input power, connect directly to power
source.
AC models – 28VDC, connect to the AC to DC power
converter.
ATTENTION: The AC/DC converter is pre mounted on the wall
bracket. Do not connect directly to any other type of power
supply!!!
Below are descriptions of the front panel indicators. Detailed troubleshooting procedures
are provided in section
6.2.1 - Status LEDs on the Repeater Front Panel
LED
Description
DL Downlink path status and RSSI indication:
Steady Green – Normal operation
Blinking Green - Low power
Orange – Input signal exceeds max. level
Red – Major alarm
Power Power\Major alarms status indication:
Steady Green – Normal operation
Orange – Major malfunction
Red – Blinking panel mask
Orange LED ON – normal operation.
Service
antenna
connections
DC Power
connection from
bracket PS
Donor antenna
connections
DL and
Power LEDs
Dry contact NFPA
alarms
Ethernet
Orange LED
DC Input is model
dependent (28VDC
or ±48VDC)