Appendix B - F/O Cleaning Procedure
NOTE: The process is demonstrated on an OMU F/O module and is similar to all F/O equipment
supplied by Axell.
Tools:
Tool Description Illustration
Fibrescope connected to a PC running the appropriate
viewing software.
It is highly recommended that some form of fibre
viewing equipment such as a Fibrescope is used to
ensure that all fibre connections are clean before
termination; failure to do so could result in poor system
performance
Lint-free swabs (box), Axell P/N 99-000127
Lint-free wipes (pack) Axell P/N 99-000125
Fujikura “One Click” cleaner, Axell P/N 98-900004.
99% isopropyl alcohol (can), Axell P/N 99-000126
Cletop type S Cassette Cleaner, Axell P/N 98-900001
© Axell Wireless Ltd Doc. No. PN 4004 BSF0038 Series-UM Rev. 1.0 55