4.3 RF Balancing
The BSF-4004 RF Balancing procedure can be performed manually (the automatic option specified
in section
4.3.2 will be available in the future) via the OMU II web interface.
4.3.1 Manual RF Balancing
NOTE: If connected locally, enter the BSF-4004 Home screen and skip to step 2.
The manual balancing procedure consists of the following steps:
• Verifying the DL RF output level is maximized by setting the required DL attenuation of the
signal.
• Setting the UL attenuation according to the DL.
• In case of noise, adjusting the UL attenuation to reduce noise
To balance the BSF-4004 UL and DL outputs
1. Access the BSF-4004 Configuration window:
• Click on the Nodes button. The below pane appears
• Click Control next to the node to be balanced.
Figure 4-4: OMU II System Nodes window
2. The resulting pane can be displayed in two views:
• Basic – default view (Basic button)
• Advanced – provides more information (Advanced button)
The dialog below shows an example of the Basic (default) view.
Note: The various elements monitoring options are described in detail in section 6.