User's Manual
Table Of Contents
- FCC Part 15
- Unauthorized Changes to Equipment
- FCC RF Exposure Limits
- Antenna Installation
- Compliance with FCC deployment rule regarding the radiation of noise
- 1 Introduction
- 2 Antenna and Repeater Installation Requirements
- 3 Installation
- 4 BSF-4004 Commissioning
- 5 BSF-4004 Full GUI Description
- 6 Monitoring, Fault Sourcing and Maintenance
- Appendix A - Specifications
- Appendix B - F/O Cleaning Procedure
AXELL BSF-4004 BSF0038 SERIES REPEATER
PRODUCT DESCRIPTION AND USER’S MANUAL
4 BSF-4004 Commissioning
After the repeater is connected, it is identified by the OMU II via the fibre connection and the unit is
commissioned from the OMU II. The commissioning process consists of a few simple steps.
To commission the BSF-4004 - overview:
1. Open an OMU II session – used to access the BSF-4004 configuration window (via OMU II).
2. Perform Optical Loss Adjustment.
3. Set the required RF attenuation and gain levels
4. Assign the unit a recognizable name (according to its location).
4.1 Open a Session to the BSF-4004 via the OMU II
1. Open a local or remote session to the host OMU II:
• Remote session – open a Browser session in the same subnet as the host OMU II and enter
the IP of the host OMU II (see OMU user manual for detailed procedure). Enter the OMU II
User Name (e.g. axell) and Password (provided by your system administrator).
• Local session– connect to the OMU II Control Module's USB or Ethernet ports. Enter the
OMU II User Name (e.g. axell) and Password (provided by your system administrator).
• After accessing an OMU II session, commission the BSF-3604 according to the following
section.
Figure 4-1: Connection to OMU II
USB cable
Ethernet cable
Connect to either the USB
port or Ethernet port
© Axell Wireless Ltd Doc. No. PN 4004 BSF0038 Series-UM Rev. 1.0 19