2.1.3 RF Cable Installation Guidelines
Required:
For all coaxial connections to/from the Repeater - high performance, flexible, low loss 50Ω
coaxial communications cable.
All cables shall be weather-resistant type
.
Cable length - determined by the Repeater installation plan. When calculating the cable length,
take into account excess cable slack so as not to limit the insertion paths.
2.1.4 F/O Cable Installation Guidelines
Use the following over the complete link between the Remote and OMU:
Use angled APC connectors at 8deg angle.
APC type ODF connections.
Cable length - determined by the Remote installation plan. When calculating the cable length,
take into account excess cable slack so as not to limit the insertion paths.
Recommended fibre-optic cable:
Single mode 9/125
2.2 Service Antenna Requirements
WARNING!!!
a. The installer is held accountable for implementing the rules required for deployment.
b. Good engineering practice must be used to avoid interference.
c. Output power should be reduced to solve any IMD interference issues”
The Service antenna type depends on the design of the indoors DAS.
2.2.1 Required Antenna Information
The following antenna requirements, specifications and site considerations should be met:
Type of installation – indoor DAS/Radiating Cable
Service area type and size
Antenna type and characteristics
Height
Length and type of coaxial cable required for connecting the antenna to the Repeater and the
attenuation.
8 Doc. No. PN 4004 BSF0038 Series-UM Rev. 1.0 © Axell Wireless Ltd