6.4 Setting Date and Time
Be sure to set the correct date and time in order to accurately timestamp all events
occurring on the CSR.
To set the Date & Time
1. From any screen, hover on the Title area and click on Date and Time.
2. Do one of the following:
Either, enter the correct date and time according to the displayed formats.
Or, click on Local Time to set the time according to the PC running the Web-GUI.
3. Click Apply.
6.5 Additional Configuration Options
Depending on your installation and supported repeater options, you may also want to:
Configure the external alarms if external alarms are connected
IP address for repeaters that will be connected to the Ethernet network after the initial
setup procedure
SNMP support requires configuring the agent and trap destination address
TCP/IP support
Modem setup for units supporting a GPRS/GSM modem
NOTE: For units managed via the AEM, no configuration procedures are required on the repeater
side; the repeater access information is configured into the AEM.
6.5.1 Configuring External Alarms
The unit supports up to two external alarms. Connected external alarms must be configured
according to the trigger (high or low) and it is recommended to assign the alarms
recognizable names (such as Door Open, High Temperature, etc.)
To configure the external alarms
1. Hover on the Title area and click on External Alarms.
2. Set the alarm Trigger:
High voltage triggers alarm
Low no voltage triggers alarm
3. Assign a description to each relevant alarm in the Description area.
4. Click Apply to save the changes.