User Manual
AXELL 3604 A284 SERIES UHF REPEATER
PRODUCT DESCRIPTION AND USER’S MANUAL
26 DOC PN 3604 A284 Series-UM © Axell Wireless Ltd
4.11.3 Switching Power ON
To switch the repeater ON
1. Open repeater door to access switches.
2. Set to ON both Power and Battery switches (located inside the repeater).
3. Connect the supplied power cable between the Repeater Power connector and the
circuit breaker.
4. Turn the repeater on from the circuit breaker.
5. Verify the LEDs from the following internal modules are indicating correct operation
(section 8.1):
Control module.
Power supply modules
NOTE: To switch power OFF set battery switch to OFF and power switch to Standby.
Note the following:
repeater is still connected to the power supply but not operational.
The backup battery is operational for five years. Refer to section 9.3 for backup battery
replacement.
The CSR supports a backup battery for last gasp in case of power failure. To power on
the unit, it is required to switch-on both power and backup battery switches.
The image below shows the location of the various power elements.
Figure 4-17 Power Elements Inside Repeater
4.11.4 Close and secure the Repeater
Close lid, fully tighten the two screws and lock repeater and continue to the next chapter:
.
Note! The two screws must be fully tightened. Failure to do so may affect the IP65 compliancy and
therefore any warranty.
Power ON/Standby
switch
Backup battery
pack
Battery (BATT) ON/OFF
switch