4.11 Power Connections
Caution! Make sure the antenna cables or 50 ohm terminations
        
repeater is turned on.
Caution! Be sure a CIRCUIT BREAKER meeting the instructions
given in this section is connected near the unit at an easily
reachable and accessible location from the unit.
4.11.1 Circuit Breaker Connections
To disconnect the unit (either manually or automatically in case of over-current), it is
required to install a circuit breaker on the wall near the unit, at an easily accessible distance
and location from the unit.
Circuit-breaker minimum requirements
10AT, 115V AC
Needs to be SAFETY approved
Requires minimum contact separation of 3mm.
Install on the wall near the unit
4.11.2 110/115v AC Power Source Connection
Cable requirements:
Cable should be NRTL (safety) approved with a minimum of 14AWG (2.5mm) per
conductor.
For safety, the GND cable must be 10mm longer than the Phase and Neutral cables.
Connect the power cable to the plinth as show below:
Phase linked to the Black cable
Neutral linked to the White
Ground to the Green where for SAFETY, the GND cable must be 10mm longer than
the Phase and Neutral cables.
Figure 4-16 115V AC Power Source Connection