Figure 4-15. External Alarm and Dry Contact Connections
NOTE: The External Alarms connections can be protected with a cover which is screwed in place.
4.10.1 External Alarm
Four external alarm sources can be connected to the repeater.
Alarm operating voltage: between 12 and 24VDC.
Alarm polarity can be configured:
Active-low - when there is no voltage the alarm indicator will turn red
Active-high - an applied voltage of between 12 and 24 V will cause the external
alarm indicator to turn red.
The repeater can supply +15 VDC to an external alarm source through pin 9 and 10.
The maximum allowed load is 100mA.
4.10.2 Relay
Relay (pin 11 and 12) can be connected to an external device to indicate an alarm.
Can be configured to trigger on any number of internal and external alarms. The
maximum current that can be supplied is 100mA.
1 External alarm 1A
2 External alarm 1B
3 External alarm 2A
4 External alarm 2B
5 External alarm 3A
6 External alarm 3B
7 External alarm 4A
8 External alarm 4B
9 Alarm +15V
10 Alarm 0V
11 Relay Output 1A
12 Relay Output 1B
13 GND
14 NC
15 NC
16 NC
17 NC
18 NC
Pin # Signal
Pin 1