4.4 Wallmount Procedure
Wall compatibility - check the suitability of the wall on which the Repeater is to be
to be fitted.
Plan mount - check the actual fixing centers (see below) and overall dimensions of
the Repeater enclosure. The Repeater is supplied with two wall mounting brackets;
when the Repeater is mounted on these brackets adequate ventilation is provided
between the Repeater and the wall to which it is fixed.
Plan connection cable clearances - the Optical, RF and power connections
located on the underside of the Repeater will need at least 300mm vertical clearance
below the Repeater to enable the connections to be made. The minimum bend
radius for Optical and RF cables must not be less than the recommendations made
by the cable manufacturer. Plan the cable runs and ensure adequate space is
available.
Allow for door opening - ensure that there is sufficient space at the front of the
Repeater to allow the door to be fully opened and for maintenance engineers to get
access to the unit with test equipment such as a spectrum analyzer. Allow an
additional 500mm of space in front of the Repeater when the door is fully open.
Fix bolts fix M6 Rawlbolts or similar (50 to 75mm in length) into the wall at the
dimensions as illustrated in figure 1 below using equipment as specified by the fixing
manufacturer. A recommended method is set out below. Care must be taken to
ensure the alignment of the four fixings. A spirit level or plumb line should be used to
ensure horizontal/vertical alignment.
Wall-mount bracket position