MBF-40 SMR700/SMR800 PS REPEATER
PRODUCT DESCRIPTION AND USER’S MANUAL
www.cobham.com/wireless Date: 28-Jan-16 Cobham Wireless – Coverage
Page | 54
Rev. 2.1 Doc. No. 00046UM
5 MONITORING AND FAULT SOURCING
MBF-40 provides the following monitoring and fault sourcing options:
• Web GUI Home screen Advanced mode – shows general status of system and components
• Web GUI Logs screen – provides logs of faults and operations
• Module LEDs – can be seen locally when opening the Repeater
This chapter describes these fault sourcing tools.
Note the following
• The Input / Output RF level power level monitoring windows are for indication only and should
not be considered a replacement for laboratory test equipment accuracy of measurement of
actual signal levels. The error of measurement will be high at low input levels.
• The normal operating range of signal measurement is as follows:
• Downlink Output range +20dBm to +43dBm
• Uplink Output range -10dBm to +5dBm