3.3.3 RF Balancing
The MBF-40 RF Balancing procedure can be performed manually (the automatic option specified in
section
3.3.3.2 will be available in the future) via the OMU II web interface.
3.3.3.1 Manual RF Balancing
NOTE: If connected locally, enter the MBF-40 Home screen and skip to step 2.
The manual balancing procedure consists of the following steps:
• Verifying the DL RF output level is maximized by setting the required DL attenuation of the
signal.
• Setting the UL attenuation according to the DL.
• In case of noise, adjusting the UL attenuation to reduce noise
To balance the MBF-40 UL and DL outputs
1. Access the MBF-40 Configuration window:
• Click on the Nodes button. The below pane appears
• Click Control next to the node to be balanced.