2.3.2 Rack Mount Installation
The supplied brackets are used to mount the repeater either on a wall or in a 19” rack. The same
brackets are used for both medium and high-power repeaters.
IMPORTANT!!
• The weight of the unit requires that two people mount the unit onto the rack.
• The signal booster must always be installed vertically with the connectors on the
underside for protection.
Horizontal installation on a bench for long time may cause
damage to the signal booster due to over-heating.
To mount the repeater in a rack
1. Use the x4 (provided) M8 Fixing Bolts and X4 Spring Washers to assemble the brackets as
illustrated below.
Figure 2-4: Rack-mount bracket position
2. Mount the repeater
vertically
in the rack,
while adhering to standard rack mounting
procedures, and secure.
Figure
2-5: Rack-mount Repeater position
X4 M8 bolts
x4 M8 spring
washers