User Manual

Table Of Contents
AXELL MBF MULI-BAND FIBER REPEATER
PRODUCT DESCRIPTION AND USERS MANUAL
© Axell Wireless Ltd 41
Flashing
(irregular)
Indicates GPSR data transfer. When a GPRS
transfer is in progress the LED goes on within 1
second after data packets were exchanged. Flash
duration in approximately 0.5s.
75ms on/75ms off/75ms on/3s off
One or more GPRS contexts activated
75ms on/3s off
Logged to network (monitoring control channels
and user interactions). No call in progress
600ms on/600ms off
No SIM card inserted, or no PIN entered, or
network search in progress, or ongoing user
authentications, or network login in progress
Off
Modem is off
Verify the remote communication either by having someone attempting to integrate the repeater from
the Axell Element Manager, or by dialling the repeater using the Repeater Maintenance Console.
Note! It is very important to dial the data number of the SIM. In case the voice number is dialled, the
call is answered, but almost immediately the call will be hung up.
7.4.2.2 SIM-card Using Single Numbering Scheme
If the network is configured using Single Numbering Scheme (SNS), some special considerations
apply.
The repeaters are by default configured so that networks using SNS always will have calls routed to
the data service in the modem. When dialling from within the network to a repeater having an SNS-
configured SIM will operate normally, since the call originator informs the system that the bearer is
of type DATA. However, when dialling from outside the network trying to connect to the repeater
can be difficult. Depending on the interface to the roaming network or to the PSTN network if an
analogue modem is used, the bearer type can default to voice. If the bearer is set to voice, the data
service cannot be converted to DATA, and a call setup cannot be completed.
Note! This is not a repeater related problem; the solution is to verify how the external network
interfaces handles the VOICE vs. DATA bearer type.
7.4.3 Configuration via PSTN (Fixed) Modem
Also for PSTN modems data call shall be used.
Select
“Configuration”
and
“Communication”