User Manual

Table Of Contents
AXELL MBF MULI-BAND FIBER REPEATER
PRODUCT DESCRIPTION AND USERS MANUAL
© Axell Wireless Ltd 17
2.7.4 Backup Battery
On the Power Supply unit a rechargeable battery pack in mounted. This part also includes
charging and supervision electronics.
The backup battery will provide the Control Module and modem with enough capacity to send an
alarm in case of input power failure.
The battery can be switched on and off. The switch is placed adjacent to the main power switch
on the power supply.
At delivery the back-up battery is connected.
The battery is replaced by lifting the battery pack out of the crate and disconnecting the cable.
2
2
.
.
8
8
P
P
o
o
w
w
e
e
r
r
O
O
N
N
2.8.1 Switching Power ON
Caution!
Make sure the antenna cables or 50 ohm terminations are connected to the repeater’s antenna
connectors before the repeater is turned on.
The rightmost switch is the one that switches the main power. The leftmost is for turning the battery
on/off.
Note! The power switch has two positions; “on” and “stand by”. In the stand by position the repeater
is still connected to the power supply but not operational.
Connector
Switch the repeater on by using the power switches on the power supply.
Note! See caution above!
There are two switches. One is for the battery and one is for the power
Power Switch