User Manual

Table Of Contents
AXELL MBF MULI-BAND FIBRE REPEATER
PRODUCT DESCRIPTION AND USERS MANUAL
14 © Axell Wireless Ltd
2
2
.
.
7
7
P
P
o
o
w
w
e
e
r
r
a
a
n
n
d
d
B
B
a
a
c
c
k
k
u
u
p
p
B
B
a
a
t
t
t
t
e
e
r
r
y
y
Caution!
Make sure the antenna cables or 50 ohm terminations are connected to the repeater’s antenna
connectors before the repeater is turned on.
The image below shows the location of the various power elements. These are described in detail in
the following sections.
2-2 Power Elements Inside Repeater
2.7.1 Connecting the Power Source
Power Source: 230 VAC 50 Hz, 115 VAC 60 Hz or -48 VDC
The -48VDC version of the power supply is designed to turn off if the supply voltage falls below
-36V (±1V). It will turn on again as the supply voltage reaches -43V (± 1V).
The power supply has a switch which allows it to be set in “on” position or in “stand by”.
Note!
A. In the stand by position the repeater is still connected to the power supply but not
operational.
B. On repeaters mounted in an extended box with two power supplies, both power supplies
needs to be switched on.
110/230 V AC power
connections
Power ON/Standby
switch
Backup battery
pack
Battery (BATT) ON/OFF
switch