AXELL MBF MULI-BAND FIBRE REPEATER
PRODUCT DESCRIPTION AND USER’S MANUAL
4 © Axell Wireless Ltd
1.6.1 Securing the Unit
The repeaters are secured with two hex
screws (M8) and can also be locked with a
key.
Note! The two screws must be fully
tightened. Failure to do so may affect the
IP65 compliancy and therefore any
warranty.
1.6.2 External Interfaces
The repeater’s interfaces are located on the underside panel.
Note! The external connections at the bottom of the repeater can be protected with a cover which is
screwed in place.
The following table provides a description of the front panel ports and connections.
Port Description
Server Service antenna connection - DIN 7/16” connector, female
Optic SC/APC fibre optic connector through which the optic fibre is routed for
internal connections (section
2.5).
Power
Plinth connection for routing power for internal connection (section
2.7)
Alarms Plinth connector for routing external alarms and relay wiring cable for
internal connections (section
2.6).
GND
Grounding lug (section
2.3)
Screws
Connectors
Lock
Power Fiber inputGround Server
antenna
External
alarms