AXELL OPTICAL MASTER UNIT
PRODUCT DESCRIPTION AND USER’S MANUAL
28 © Axell Wireless Ltd
Go through all
racks and all fibre
optic converters
one by one and
initiate the
compensation
process
First chose the rack and then the fibre optic converter.
In an OMU that contains only one sub
rack – this rack is called “Rack 1”
Additional sub-racks/slave OMUs
that are linked to the master OMU are
named “Rack 2, 3 and 4”.
Each fibre optic converter is
numbered from left to right in each
sub-rack.
For each rack/fiberfibre optic converter please wait for the system to
respond.
The system will respond with a description as below.
In the response above the Status is “OK” (6 lines from the bottom).
If the system responds with an error message the fibre link need to be
checked. If there is nothing wrong with the link it is possible that the fibre
loss is too big for the system to be able to compensate for it.
Go through all racks and all fibre optic converters one by one and initiate the
compensation process.