5.5 Install the OMU and Set up OMU-Repeater
System
For information about how to install the OMU which will supply the input signal to the repeater please refer
to the OMU Manual. In the OMU Manual there is also information about how to calculate link budgets for a
whole OMU-Repeater system.
5.6 Configure the Repeater
The following pages will guide you through the configuration of a repeater utilizing the Repeater
Maintenance Console (RMC) software. Configuration of a repeater is made partially on site and partially
remotely through the AEM. At site the RF parameters are set and verified, the repeater is given a name (a tag)
and the remote communication is set and verified. All other configuration can, and should be made from the
AEM.
5.6.1 Set up RF Configuration
Configuration of the repeater amplification can be made locally. If the repeater is connected to an OMU the
configuration can also be made via this OMU. See OMU User’s Manual.
Note! This is an example from a single band repeater. Other repeaters will have similar features.
Ensure online
communication with
the repeater
Select “RF/Status” window
Alarms and general
information
Uplink attenuation
Uplink input and
output power
Downlink
attenuation
Downlink input and
output power
This shows a single band repeater with no RF signals
Check that the fibre
is OK
Make sure there are no alarms relating to the fibre.