User Manual

MBF, Multi Band Repeater
PRODUCT DESCRIPTION AND USER'S MANUAL
© Axell Wireless Ltd A 200 93 00, rev E 79 (105)
with malfunction
Examples
Input
Power
+6V +15V +28V
LED 1 is flashing slowly, LED 2 – 4 are flashing slowly
(once every 10 seconds)
=> power supply unit is operating without problem
Input
Power
+6V +15V +28V
LED 1 is flashing slowly, one or two of the red LEDs
are flashing quickly
=> Input power is operating but there is a problem with
some of the other voltages
Input
Power
+6V +15V +28V
LED 1 is flashing slowly, all of the red LEDs are
flashing quickly
=> Input power is out and unit is operating on backup
battery
Check Control
Module LEDs
The Control Module has four LEDs which give information regarding the status
of the repeater and if someone is logged on to the repeater.
If the repeater is configured as a system slave the two LEDs MDM Power and
MDM Status do not fill any function and can be disregarded.
L
O
G
I
N
S
T
A
T
U
S
M
D
M
P
W
R
M
D
M
S
T
A
T
U
S
Blue LED - Login
Quick flash
Control Module switched on, someone
logged in locally and/or remotely
Off
(except for a quick flash every 10th
second)
Control Module switched on, no one
logged in
Off
(permanent)
Control Module switched OFF
Red LED - Status
Quick flash
Control Module switched on, one or
more errors/alarms detected
Off
(except for a quick flash every 10th
second)
Control Module switched on, status OK
Off
(permanent)
Control Module switched off
Green LED – Modem Power