© Axell Wireless Ltd A 200 93 00, rev E 77 (105)
External Alarm
Four external alarm sources can be connected to the repeater. These alarms operate on
a voltage between 12 and 24VDC. The presence or absence of this voltage will trigger
the alarm depending on how the alarm polarity has been configured.
The alarms can be configured active-low or active-high, so that the alarm is given
either in the presence or absence of applied power. Active high means that an applied
voltage of between 12 and 24 V will cause the external alarm indicator to turn red.
Active low means that when there is no voltage the alarm indicator will turn red. The
repeater can supply +15 VDC to an external alarm source through pin 9 and 10. The
maximum allowed load is 100mA.
The repeater contains a relay (pin 11 and 12) that can be connected to an external
device to indicate an alarm. The relay can be configured to trigger on any number of
internal and external alarms. The maximum current that can be supplied is 100mA.
5.2.8 Close Repeater
Close repeater Close lid and lock repeater, or continue with the next section: Start-up the Repeater.
Note! The two screws must be fully tightened. Failure to do so may affect the IP65
compliancy and therefore any warranty.