User Manual
MBF, Multi Band Repeater
PRODUCT DESCRIPTION AND USER'S MANUAL
© Axell Wireless Ltd A 200 93 00, rev E 76 (105)
The -48VDC version of the power supply is designed to turn off if the supply
voltage falls below -36V (±1V), not to drain the feeding battery. It will turn on again
as the supply voltage reaches -43V (± 1V).
Back-up battery
Backup Battery
There is a back-up battery installed in connection with the power supply. If there is a
power failure the battery will supply enough power to the Control Module and the
Fibre Optic Converter in the repeater to send information about the power failure.
The backup battery can be switched on and off separately. The switch is placed
adjacent to the main power switch on the power supply.
At delivery the back-up battery is connected.
The battery is replaced by lifting the battery pack out of the crate and disconnecting
the cable.
Connector
5.2.7 Connect External Alarms
Connect external
alarms
The repeater is equipped with an external alarm interface card. The connector plinth
for the external alarms is located at the bottom of the repeater.
The strain relief fitting in is a Pg 13.5 suitable for a 6-12 mm cable diameter.
Connect the alarm cords to the plinth according to the pin layout below (in the
standard version pins 14 – 18 are not used).
1 External alarm 1A
2 External alarm 1B
3 External alarm 2A
4 External alarm 2B
5 External alarm 3A
6 External alarm 3B
7 External alarm 4A
8 External alarm 4B
9 Alarm +15V
10 Alarm 0V
11 Relay Output 1A
12 Relay Output 1B
13 GND
14 NC
15 NC
16 NC
17 NC
18 NC
Pin # Signal
Pin 1