User Manual
MBF, Multi Band Repeater
PRODUCT DESCRIPTION AND USER'S MANUAL
© Axell Wireless Ltd A 200 93 00, rev E 57 (105)
Field Format
# of
char
Description
actual device.
For example, the Byte 1 status is sent as Hex ‘8’, which is extracted to 1000.
Bit 3 Bit 2 Bit 1 Bit 0
TXO Fibre
Optic Unit 1
TXO Fibre
Optic Unit 2
TXO Fibre Optic
Unit 3
TXO Fibre Optic
Unit 4
EX1/EX2/EX3/EX4 NNNN 4 Status of external alarm inputs
DOO N 1 Door status
NMP X 1
Communications path to node master in the Communications Multiplexer. If not
used, a dash is reported.
RCH NNNNNN 6 Repetition Cycle for Heartbeat reports
4.5.3 Heartbeat Log
Recent heartbeats can be viewed in a log that shows details about the alarms.
Monitor Alarm Log via the RMC
Select “Alarm
Log” and
“Heartbeat Log”
Message No
Date/Time
Description
Retransmissions
Message
The heartbeat message format is described in section 4.5.2 Heartbeat Format.
4.6 RF Parameters
The attenuation can be changed in 1 dB steps. If the attenuation for example is set to 15 dB, the repeater is
downgraded 15 dB from its maximum performance.
Maximum gain in the repeater can be read from the Product Information menu (choose
Configuration/Product).