User Manual

MBF, Multi Band Repeater
PRODUCT DESCRIPTION AND USER'S MANUAL
© Axell Wireless Ltd A 200 93 00, rev E 53 (105)
Note! If the time is adjusted by a user logged in to the repeater, once the user logs out, a heartbeat is sent to
the AEM to ensure that the time is correctly synchronized.
4.5.2 Heartbeat Format
The heartbeat report is transmitted as an ASCII text string, with a number of fields representing the RF-
configuration and status parameters, each field separated by a blank/white space.
Using the Axell Element Manager to control the repeater, the heartbeat report is delivered to the Transceiver
for further processing in the AEM system.
Field Format
# of
char
Description
Repeater ID XX-YY-ZZZZ 10
Message no NNNNNNNNN 9
State STATE 5
Date DDMMYY 6
Time HHMMSS 6
IHU
NNNNNNNNN
NNN
12 Installed hardware units.
0 = not installed
1 = installed
Hardware order: PSUP1, PSUP2, RefGen, RadioUnit1, RadioUnit2, RadioUnit3,
RadioUnit4, FiberOptic1, FiberOptic2, FiberOptic3, FiberOptic4,
Comm.Multiplexer
ATD XXYYZZWW 8 Attenuation in downlink
ATU XXYYZZWW 8 Attenuation in uplink
LVD/LVU JKLMXYZW 4 Output Power Enabled / Disabled in downlink/uplink
AMD/AMU NN 2
Status of amplifier chain downlink/uplink.
These values are Hex Coded, and should be used in conjunction with COM status for
actual device.
For example, the Byte 1 status is sent as Hex ‘8’, which is extracted to 1000.
Byte 1
Bit 3 Bit 2 Bit 1 Bit 0
Amplifier Chain
1 Downlink
Amplifier Chain
2 Downlink
Amplifier Chain
3 Downlink
Amplifier Chain 4
Downlink
Byte 2
Bit 3 Bit 2 Bit 1 Bit 0
Amplifier Chain
1 Uplink
Amplifier Chain
2 Uplink
Amplifier Chain
3 Uplink
Amplifier Chain 4
Uplink
ASD N 1
Status of amplifier saturation downlink
These values are Hex Coded, and should be used in conjunction with COM status for
actual device.
For example, the Byte 1 status is sent as Hex ‘8’, which is extracted to 1000.
Bit 3 Bit 2 Bit 1 Bit 0
Amplifier Chain
1 Downlink
Amplifier Chain
2 Downlink
Amplifier Chain
3 Downlink
Amplifier Chain 4
Downlink
BAT N 1 Status of Battery Charge
CMM N 1
Status of communication between Radio Board and MCPA.
These values are Hex Coded, and should be used in conjunction with COM status for