4.4.8 Alarm Monitoring
The alarms can be monitored via the RMC. Each alarm has an indicator that is either green or red.
See also reference to section 4.4.1 Alarm Sources.
Uplink Related Alarms
Amplifier, AU1-4. The repeater measures the input signal level
in the uplink and compares it to expected output power with
regards to set attenuation. If the output power is too high or too
low an alarm is triggered.
Downlink Related Alarms
Amplifier, AD1-4. The repeater measures the input signal level
in the downlink and compares it to expected output power with
regards to set attenuation. If the output power is too high or too
low an alarm is triggered.
Saturation Status, ASD. Measures saturation in the downlink.
Power Level, PD1-4. Measures the output power in the
downlink.