© Axell Wireless Ltd A 200 93 00, rev E 45 (105)
4.4.5 Alarm Class
Each alarm belongs to a class. The defined classes are:
Class Description
CO Communications
QS Quality of service
PR Software or processing
EQ Hardware equipment
EN Environment (enclosing or surrounding equipment)
All alarms are configured to a class at delivery but can be changed by the user. The external alarms do not
have a classification at delivery, but can be set by the user.
4.4.6 Alarm Severity
Alarms can be of five different severity levels.
Severity Level Description
Critical
A critical error has occurred which affects the functionality of the repeater. This type
of alarm requires immediate action.
Major
A major error has occurred. This type of alarm should be investigated within a short
time.
Minor
A minor error has occurred. This type of alarm should be investigated, but is not
urgent.
Warning
Something has occurred that does not affect the operation of the repeater but may be
important to notice. For example, someone has logged on to the repeater.
Cleared
A cleared alarm. This is the end of alarm.
The severity can be defined for each alarm source in the Alarm Configuration screen in the RMC. It is
recommended not to change the default settings.