Alarm Threshold
Initial alarm End of Alarm
Three minutes have elapsed and a
new alarm is transmitted
Minimum alarm
repetition
Alarm level
Time
This illustration shows an alarm source with an upper threshold, and a fluctuating level around the alarm
threshold. In this example, the first alarm will be sent as indicated. The next alarm will be transmitted after
three minutes, when the minimum alarm repetition period has elapsed.
In this configuration a new alarm will not be sent before three minutes have elapsed. This variable can be set
from 0 to 99. If it is set to 0 the feature is disabled.
Set Minimum Alarm Repetition Cycle
Select
“Configuration “ and
“Reports”
4.4.3 Alarm Retransmissions and Acknowledgements
As soon as the repeater detects an alarm or an end of alarm, a connection to the Axell Element Manager is
established and the alarm event is reported.
The 2 000 latest alarms and end of alarms are stored in the repeater’s local alarm log. In case an alarm is not
acknowledged the alarm will be retransmitted to the AEM after a configurable number of minutes. Allowed
values are 0 to 999. Default retransmit interval is 10 minutes.
The retransmission will be repeated a configurable number of times. This variable can be set from 0 to 99.
Default number of retries is three
Set Number of Retransmissions and Repetition Cycle for Non-acknowledged
Alarms