User Manual
MBF, Multi Band Repeater
PRODUCT DESCRIPTION AND USER'S MANUAL
© Axell Wireless Ltd A 200 93 00, rev E 27 (105)
The Control Module has four LEDs which give information regarding
the status of the repeater and if someone is logged on to the repeater.
If the repeater is configured as a system slave the two LEDs MDM
Power and MDM Status do not fill any function and can be disregarded.
L
O
G
I
N
S
T
A
T
U
S
M
D
M
P
W
R
M
D
M
S
T
A
T
U
S
Blue LED - Login
Quick flash Control Module switched on, someone logged in locally and/or remotely
Off (except for a quick flash every
10th second)
Control Module switched on, no one logged in
Off (permanent) Control Module switched OFF
Red LED - Status
Quick flash Control Module switched on, one or more errors/alarms detected
Off (except for a quick flash every
10th second)
Control Module switched on, status OK
Off (permanent) Control Module switched off
Green LED – Modem Status
On Depending on type of call:
Voice call: Connected to remote party
Data call: Connected to remote party or exchange of parameters while setting up
or disconnecting a call
Flashing
(irregular)
Indicates GPSR data transfer. When a GPRS transfer is in progress the LED
goes on within 1 second after data packets were exchanged. Flash duration in
approximately 0.5s.
75ms on/75ms off/75ms on/3s off
One or more GPRS contexts activated
75ms on/3s off
Logged to network (monitoring control channels and user interactions). No call
in progress
600ms on/600ms off
No SIM card inserted, or no PIN entered, or network search in progress, or
ongoing user authentications, or network login in progress
Off Modem is off
Green LED – Modem Power
On Modem Power is on
Off Modem Power is off