User Manual

MBF, Multi Band Repeater
PRODUCT DESCRIPTION AND USER'S MANUAL
© Axell Wireless Ltd A 200 93 00, rev E 24 (105)
The repeaters are closed with two hex screws,
M8.
As a complement the repeaters can be locked
with a key.
Note! The two screws must be fully tightened.
Failure to do so may affect the IP65 compliancy
and therefore any warranty.
The external connections at the bottom of the
repeater can be protected with a cover which is
screwed in place.
Screws
Connectors
Lock
The repeaters are designed to be mounted on a wall or in a 19” rack. They should always be mounted in a
vertical position with the connectors facing downwards.
3.5 Connections
All connections are placed at the bottom panel of the repeater.
Power Fiber inputGround Server
antenna
External
alarms
Antenna connection is DIN 7/16” connector, female
Fibre connector is SC/APC. It is placed on the fibre optic converter(s) inside the repeater
Plinth connection for power input is described in section 5 Installation
Plinth connector for external alarms is described in section 5 Installation
Note!
APC connectors need to be used
throughout the whole link between the OMU and the repeater.
Also all ODF connections need to be of the same type.
3.6 Building Blocks
The repeaters consist of the following main building blocks.