User Manual

MBF, Multi Band Repeater
PRODUCT DESCRIPTION AND USER'S MANUAL
© Axell Wireless Ltd A 200 93 00, rev E 70 (105)
Example of a sun shield
IP65 Casing Note! The repeater box should be closed using the two screws. The screws must be
fully tightened. Failure to do so may affect the IP65 compliancy and therefore any
warranty.
5.2.3 Ensure Proper Grounding
Connect the
grounding
protection
Ensure that good grounding protection measures are taken to create a
reliable repeater site. Make sure to use adequately dimensioned
grounding cables. The minimum recommended conductive area for a
grounding cable is 16mm
2.
The antenna cabling should be connected to ground every 10m by a
reliable grounding kit.
Make sure the grounding product used is suitable for the kind and size
of cable being used.
Connect the repeater box bolt to the same ground.
Ground
Ground connector on repeater