4.11.2.1 Modem Configuration, not using GPRS
Select
“Configuration” and
“Communication”
Select Data Call
Initialization string
Connect times
AEM addressed are
set via the AEM
2004-01-01
Select Data Call
Set the modem initialization string. This string differs between networks. Primary
recommendation is AT+CBST=71,0,1;\Q3. If remote communication cannot be
established try 7,0,1 or 0,0,1 or 7,0,3. For more information please refer to the
section on Troubleshooting Remote Communication.
Tick “Enable Automatic Modem Power Cycling” for the modem to be power
cycled once every 24 hours. Set the time at which the modem should be tested. This
function ensures that the repeater always is logged in to the network.
4.11.2.2 Modem Configuration, using GPRS