User Manual

Table Of Contents
Optical Master Unit
PRODUCT DESCRIPTION AND USER’S MANUAL
© Axell Wireless Ltd A1829300 rev H 61 (86)
4.6 Initiate Local Communication
4.6.1 RMC Communication
Connect to the LMT
port
Connect the computer to the LMT port on the Control Module via a DB9 male
connector with serial RS232 interface.
The communication parameters are set automatically by the RMC
Select “Cable”
connection and
communication port
Enter user name and
password
Several users at a time can be logged on, for instance one locally via the RS232
interface and one remotely via modem or Ethernet.
There is one default user name and password defined for the OMU.
User Name Password
avitec AvitecPasswd
Note! Both the user name and the password are case sensitive.
Note! Do not use the number pad when entering numbers.
4.6.2 RMC Work Views
There are three different work views to choose from in the RMC
Console Mode
The console mode displays a large number of repeater parameters and contains a number of console pages. It
adjusts its user interface to adapt to the features of the connected repeater.