9.1.1 Usage
Attribute Type: Read-Only
Depending on configuration, an optical master unit can consist of one to four racks,
where rack 1 is the master rack and rack 2 to 4 are slave racks. This attribute displays a
number of voltages as measured in the configured racks.
Levels are displayed for all racks configured in the system, and if rack is not available, a
'-' (dash) is reported in corresponding position.
Format:
<PW1:1> .. <PW1:4> <PW2:1> .. <PW2:4> <PW3-RCB:1> .. <PW3-RCB:4> <PW3-
SPLIT:1> .. <PW3-SPLIT:4> <PW3-COMB:1> .. <PW3-COMB:4> <PW4:1> <BAT:1>
where
<PW1:1> .. <PW1:4> is the +28.0 V levels with one decimal resolution and a leading +
sign as measured in rack 1 to rack 4.
<PW2:1> .. <PW2:4> is the +15.0 V levels with one decimal resolution and a leading +
sign as measured in rack 1 to rack 4.
<PW3-RCB:1> .. <PW3-RCB:4> is the +6.45 V levels with two decimals resolution and
a leading + sign as measured in Rack Communications Board in racks 1 to 4.
<PW3-SPLIT:1> .. <PW3-SPLIT:4> is the +6.45 V levels with two decimals resolution
and a leading + sign as measured in Splitter Board in racks 1 to 4.
<PW3-COMB:1> .. <PW3-COMB:4> is the +6.45 V levels with two decimals resolution
and a leading + sign as measured in Combiner Board in racks 1 to 4.
<PW4:1> is the +6.45 backup power level with two decimals resolution and a leading +
sign as measured in rack 1.
<BAT:1> is the battery level with one decimal resolution and a leading + sign as
measured in rack 1.
Example (assuming system is equipped with master and one slave rack power
supplies):
GET PLV
Reply:
+28.1 +28.0 - - +15.0 +15.0 - - +6.41 +6.43 - - +6.42 +6.45 - - +6.41
+6.42 - - +6.46 +11.1
displaying the power supply distribution throughout the optical master unit.
9.2 TEL – Temperature Levels
Displays temperatures as measured throughout the Optical Master Unit.
9.2.1 Usage
Attribute type: Read only
This attribute displays all temperatures as measured in the different boards of the optical
master unit.
Format:
<CTRL> <RCB:1> .. <RCB:4> <Fiber Optic Module 1:1> .. <Fiber Optic Module
4:6>
where temperature for each of the devices is presented with one decimal resolution and a
leading + or minus sign.
If data is not available, or hardware for position is not configured, a '-' (dash) is presented
in corresponding position.
Example:
GET TEL
Reply:
+31.4 +31.1 +30.1 - - +30.9 +31.2 +30.0 +30.9 +31.1 - +31.5 +31.4 +32.0 -
- - - - - - - - - - - - - -
indicating the different temperature levels throughout the Optical Master Unit.