User Manual

Table Of Contents
Document name:
OMU Commands and Attributes 1.0.0 v1.0
Version:
1.0
Example:
GET SZP
Reply:
000000000010000---------
indicating that synthesizer in rack 2, slot 4 is unlocked, and that reason for failure should
be investigated.
6.17 TEM – Status of Controller Temperature
Displays status of temperature as measured in the repeater controller.
6.17.1 Usage
Attribute type: Read only
This attribute replies with status of the temperature as measured in the repeater
controller.
Format:
<TEM>
where
0 means status is OK
1 means status is ERROR
- (dash) means data is not available (not yet measured).
Example:
GET TEM
Reply:
1
indicating that temperature as measured in controller is outside allowed interval (as
configured with attribute ALA TEM).
Current temperature can be read out using attribute TEL.
6.18 TXO – Status of Transmitted Optical Level
This attribute replies with the status of the transmitted optical level alarm source.
6.18.1 Usage
Attribute type: Read only
Transmitted optical power level is constantly monitored to ensure functionality of the
system. In case the optical transmitter for some reason fails (hardware failure), an alarm
is triggered.
This attribute replies with the status of the transmitted optical level alarm source.
Format:
<TXO1:1>..<TXO1:6><TXO2:1>..<TXO4:6>
where reply is
0 if status is OK.
1 if status is ERROR.
- (dash) if measured data is not available (communications error or improperly
configured system).
Example:
GET TXO
Reply:
00000000000010----00----
indicating that something is malfunctioning with the optical transmitter in rack3, slot 1.
Reason for failure should be investigated.
20(45)