Byte 6: <NCO:21><NCO:22><NCO:23><NCO:24>
<PW1> is status of Power Supply 1 as measured in Rack Communication Boards
<PW2> is status of Power Supply 2 as measured in Rack Communication Boards
<PW3> is status of Power Supply 3 as measured in Rack Communication Boards and
OMU Splitters. Hex Coded as:
Byte 1: <PW3:RCB:1><PW3:RCB:2><PW3:RCB:3><PW3:RCB:4>
Byte 2: <PW3:SPLIT:1><PW3:SPLIT:2><PW3:SPLIT:3><PW3:SPLIT:4>
Byte 3: <PW3:COMB:1><PW3:COMB:2><PW3:COMB:3><PW3:COMB:4>
<PW4> is status of Power Supply 4 as measured in Rack Oommuncations Board 1.
<RBT> is Radio Board Temperature as measured in Rack Communication Boards and
Fiber Optic Modules. Hex Coded as:
Byte 1: <RBT:RCB:1><RBT:RCB:2><RBT:RCB:3><RBT:RCB:4>
Byte 2: <RBT:FO 1:1><RBT:FO 1:2><RBT:FO 1:3><RBT:FO 1:4>
Byte 3: <RBT:FO 1:5><RBT:FO 1:6><RBT:FO 2:1><RBT:FO 2:2>
Byte 4: <RBT:FO 2:3><RBT:FO 2:4><RBT:FO 2:5><RBT:FO 2:6>
Byte 5: <RBT:FO 3:1><RBT:FO 3:2><RBT:FO 3:3><RBT:FO 3:4>
Byte 6: <RBT:FO 3:5><RBT:FO 3:6><RBT:FO 4:1><RBT:FO 4:2>
Byte 7: <RBT:FO 4:3><RBT:FO 4:4><RBT:FO 4:5><RBT:FO 4:6>
<RXO> is status of Received Optical Level as measured in Fiber Optic Modules. Hex
coded as:
Byte 1: <RXO:FO 1:1><RXO:FO 1:2><RXO:FO 1:3><RXO:FO 1:4>
Byte 2: <RXO:FO 1:5><RXO:FO 1:6><RXO:FO 2:1><RXO:FO 2:2>
Byte 3: <RXO:FO 2:3><RXO:FO 2:4><RXO:FO 2:5><RXO:FO 2:6>
Byte 4: <RXO:FO 3:1><RXO:FO 3:2><RXO:FO 3:3><RXO:FO 3:4>
Byte 5: <RXO:FO 3:5><RXO:FO 3:6><RXO:FO 4:1><RXO:FO 4:2>
Byte 6: <RXO:FO 4:3><RXO:FO 4:4><RXO:FO 4:5><RXO:FO 4:6>
<SZP> is synthesizer lock status for Pilot Tone Generator as measured in Fiber Optic
Modules. Hex coded as:
Byte 1: <SZP:FO 1:1><SZP:FO 1:2><SZP:FO 1:3><SZP:FO 1:4>
Byte 2: <SZP:FO 1:5><SZP:FO 1:6><SZP:FO 2:1><SZP:FO 2:2>
Byte 3: <SZP:FO 2:3><SZP:FO 2:4><SZP:FO 2:5><SZP:FO 2:6>
Byte 4: <SZP:FO 3:1><SZP:FO 3:2><SZP:FO 3:3><SZP:FO 3:4>
Byte 5: <SZP:FO 3:5><SZP:FO 3:6><SZP:FO 4:1><SZP:FO 4:2>
Byte 6: <SZP:FO 4:3><SZP:FO 4:4><SZP:FO 4:5><SZP:FO 4:6>
<TEM> is temperature status as measured in controller.
<TXO> is status of Transmitted Optical Level as measured in Fiber Optic Modules. Hex
coded as:
Byte 1: <TXO:FO 1:1><TXO:FO 1:2><TXO:FO 1:3><TXO:FO 1:4>
Byte 2: <TXO:FO 1:5><TXO:FO 1:6><TXO:FO 2:1><TXO:FO 2:2>
Byte 3: <TXO:FO 2:3><TXO:FO 2:4><TXO:FO 2:5><TXO:FO 2:6>
Byte 4: <TXO:FO 3:1><TXO:FO 3:2><TXO:FO 3:3><TXO:FO 3:4>
Byte 5: <TXO:FO 3:5><TXO:FO 3:6><TXO:FO 4:1><TXO:FO 4:2>
Byte 6: <TXO:FO 4:3><TXO:FO 4:4><TXO:FO 4:5><TXO:FO 4:6>
<ILD> is status of input level downlink as measured in Splitter Boards.
<EX1/EX2/EX3/EX4> is status of external alarms 1 – 4.
Value can be:
0 means status is OK
1 means status is ERROR
- (dash) means data is not available (not yet measured).
18(45)