OMU Commands and Attributes 1.0.0 v1.0
Version:
1.0
meaning that there are three racks installed, power supply 3 in Rack Communications
Board second rack is in error, and that all other measured power supplies are OK.
6.12 PW4 - Status of Power Supply 4
Gives status of the power supply 4 as measured in the first rack.
6.12.1 Usage
Attribute type: Read only
This attribute replies with status of the Power Supply 4 (+6.45 V) as measured in the first
rack (master rack).
Power Supply 4 feeds the controller and modem with power that is battery backed up,
meaning that in case of a power failure it is still possible to report that repeater coverage
has disappeared.
Power Supplies are measured in the Rack Communication Boards (RCB) of the system.
Format:
<PW4>
where
<PW4> is status of the backup power supply +6.45 V as measured in the RCB of the first
rack.
Value can be:
0 means status is OK
1 means status is ERROR
- (dash) means data is not available(not yet measured or communications error with
RCB).
Example:
GET PW4
Reply:
1
meaning that power supply 4 is measured as not being within allowed interval in first
rack (master rack).
6.13 RBT – Status of Radio Board Temperatures
Gives status of the radio board temperatures as measured throughout the optical master
unit.
6.13.1 Usage
Attribute type: Read only
This attribute replies with status of the Radio Board Temperature alarm sources as
measured throughout the repeater.
Format:
<RCBD1>..<RCBD4> <FOMASTER1:1>..<FOMASTER1:6>
<FOMASTER2:1>..<FOMASTER2:6> <FOMASTER3:1>..<FOMASTER3:6>
<FOMASTER4:1>..<FOMASTER4:6>
where
<RCBD1>..<RCBD4> is status of board temperatures in Rack Communications Board 1
to 4.
<FOMASTER1:1>..<FOMASTER1:6> is status of radio board temperatures in Fiber
Optic Modules 1 to 6 in rack 1.
<FOMASTER2:1>..<FOMASTER2:6> is status of radio board temperatures in Fiber
Optic Modules 1 to 6 in rack 2.
<FOMASTER3:1>..<FOMASTER3:6> is status of radio board temperatures in Fiber
Optic Modules 1 to 6 in rack 3.
<FOMASTER4:1>..<FOMASTER4:6> is status of radio board temperatures in Fiber
Optic Modules 1 to 6 in rack 4.