User Manual

Table Of Contents
Document name:
OMU Commands and Attributes 1.0.0 v1.0
Version:
1.0
6.5 ALL - Compact Message Status Parameters in Optical Master Unit
A compact message of all RF and status parameters in the repeater.
6.5.1 Usage
Attribute type: Read only
This attribute replies with the same information as in the heartbeat sent to the Axell
Element Manager, except the header information (Repeater ID, STATE, Message # ,
Time and Date ). Please refer to Heartbeat Reports format.
6.6 BAT – Status of battery charge
Displays status of the battery charge.
6.6.1 Usage
Attribute Type: Read-Only
The optical master unit is equipped with a battery backup, which feeds controller and the
modem with power during a power failure. This battery backup ensures that the optical
master unit is able to inform the Axell Element Manager that the repeater network
coverage is out.
This attribute replies with the status of the battery charge. A too low battery charge
probably means that the optical master unit is back from a power failure and that the
battery is not fully charged yet, while a too high battery voltage might indicate that the
battery pack needs replacement.
Current battery level can be read out with attribute PLV, while battery level
configurations are manipulated with attribute ALA BAT.
Battery Level is measured in the Rack Communication Boards (RCB) of the master rack.
Format:
<BAT>
where
<BAT> is battery status.
0 if status is OK
1 if status is ERROR
- (dash) if measured data is not available (communications error or improperly
configured system).
Example:
GET BAT
Reply:
1
indicating that battery status is in error.
6.7 COM – Status of Communication with Active Devices
Displays status of communication between controller and active devices.
6.7.1 Usage
Attribute type: Read only
Gives status of the communication between the controller and the active devices. A
communications alarm might indicate a failing module an improperly configured module
or a broken cable
Format:
<RCB1>..<RCB4> <SPLIT1>..<SPLIT4> <COMB1>..<COMB4>
<FOMASTER1:1>..<FOMASTER1:6> <FOMASTER2:1>..<FOMASTER2:6>
<FOMASTER3:1>..<FOMASTER3:6> <FOMASTER4:1>..<FOMASTER4:6>
where
<RCB1>..<RCB4> is status on communication with Rack Communications Board 1 to 4.
<SPLIT1>..<SPLIT4> is status on communication with Splitter Board 1 to 4.
12(45)