6 ALARM CONFIGURATIONS
The following commands and attributes are implemented for the OMU target alarm
configurations, as an add-on to the Common part.
6.1 AC2 – Compressed Alarm Severity and Alarm Class Configurations
A compact message retrieving alarm severity and alarm class for a number of alarm
sources.
6.1.1 Usage
Attribute type: Read only
This is a compact message to retrieve Severity and Class of the different alarm sources.
BAT, COM, CRC, NCO, PW1, PW2, PW3, PW4, RBT, RXO, SZP, TEM , TXO and
ILD
Format:
<SevBAT> <ClassBAT> <SevCOM> <ClassCOM> .. <SevILD> <ClassILD>
Example:
GET AC2
Replies:
WA EQ CR EQ WA EQ CR EN CR EQ CR EQ CR EQ CR EQ CR EQ CR EN CR EN WA EN
CR EN CR EN
which are the severities and classes for the alarm sources BAT..ILD.
Note! The alarm severities and alarm classes can also be read and set
with commands
GET/SET ASE
and
GET/SET ACL
6.2 AL4 - Compressed Alarm Format
A compact message retrieving alarm configurations for BAT, COM, CRC, NCO and
PW1.
6.2.1 Usage
Attribute type: Read only
Same as attribute AL1, but replies with configuration for alarm sources BAT, COM,
CRC, NCO and PW1.
6.3 AL5 - Compressed Alarm Format
A compact message retrieving alarm configurations for PW2, PW3, PW4, RXO and
RBT.
6.3.1 Usage
Attribute type: Read only
Same as attribute AL1, but replies with configuration for alarm sources PW2, PW3,
PW4, RXO and RBT.
6.4 AL6 - Compressed Alarm Format
A compact message retrieving alarm configurations for SZP, TEM, TXO and ILD.
6.4.1 Usage
Attribute type: Read only
Same as attribute AL1, but replies with configuration for alarm sources SZP, TEM, TXO
and ILD.
11(45)