User Manual

Table Of Contents
Document Name: Common Commands and Attributes v1.3.0 Revision: 1.2
10.9 MDD – Target Model Description
10.9.1 Overview
This attribute returns a textual string, describing the type of equipment being
controlled.
10.9.2 Usage
Attribute type: Read only
The target model description replies with a verbose output of the type of equipment
being monitored by this controller.
Format:
<Textual Model Description>
being a string with a maximum length of 140 characters.
Example:
GET MDD
Reply:
Channel Selective EDGE/GSM 4-channel Repeater on 900 MHz band
being a detailed description of the actual equipment type.
10.10 MSG - Message Counter
10.10.1 Overview
This displays the value of the system event counter.
10.10.2 Usage
Attribute type: Read only
For each report or alarm being transmitted to the Axell Element Manager, a
message counter is increased, giving each alarm and report a unique system event
number in the system. This attribute displays current value of the counter.
Format:
<Message Counter>
where the <Message Counter> value is from 0 to 231.
Example:
GET MSG
Reply:
16471
indicating that the value of the system event counter currently is 16471.
Common Commands and Attributes 66/123