to 20 minutes.
Example:
GET RCR
Reply:
3
meaning that after a failed report transmission, a new attept will be made after 3
minutes.
Example:
SET RCR 2
sets the time between retransmissions to 2 minutes.
9.7 ACT HBT – Request Heartbeat Transmission
9.7.1 Overview
This command forces a transmission of a heartbeat report.
9.7.2 Usage
Attribute type: Write-Only Action
This command is used to transmit heartbeat reports to the Axell Element Manager.
This can be used to force a heartbeat synchronization.
Format:
ACT HBT
caused the heartbeat report to be transmitted as soon as the configured
communications interface is available.
Example:
ACT HBT
will, if logged in locally, perform an immediate connection to the Axell Element
Manager, and the heartbeat report to be delivered.
9.8 ACT CHB – Clear Heartbeat Log
9.8.1 Overview
This command is used to clear all the entries in the heartbeat log.
9.8.2 Usage
Attribute type: Write-Only Action
This action clears all heartbeats from the heartbeat log, and requires Read and
Write access when logged in. Via SMS, this can only be performed by the Main
Address.
Common Commands and Attributes 59/123