Document Name: Common Commands and Attributes v1.3.0 Revision: 1.2
SET SMC +46705008999
changes the SMSC address to +46705008999.
8.22 SPO – Primary Port Number
8.22.1 Overview
This configures what port number to use on secondary address when using TCP/IP.
8.22.2 Usage
Attribute type: Read and Write
This attribute is used together with SSC to build complete connection parameters
when using TCP/IP to connect to the Axell Element Manager.
Attribute configures what port number on the Axell Element Manager should be
connected to.
Format on getting parameter:
GET SPO
Reply:
<Port>
where <Port> is the port number that Axell Element Manager on IP address as
defined by attribute SSC is listening on. Valid <Port> values are 1-65 535.
Example:
GET SPO
Reply:
1025
meaning that controller will attempt to connect on port 1025 on the Axell Element
Manager when delivering alarms and reports.
Example:
SET SPO 8087
changes this port number to 8087.
8.23 SSC – Secondary Service Center
8.23.1 Overview
Used to configure the backup OMC address in case it is not possible to contact
primary address.
8.23.2 Usage
Attribute type: Read and Write
When controller is configured for data call or if TCP/IP is used (GPRS or Ethernet),
and the controller fails to connect to the primary service center (configured with the
attribute ASC), the controller will automatically switch over to the secondary service
Common Commands and Attributes 50/123