8.17 PPO – Primary Port Number
8.17.1 Overview
This configures what port number to use on primary address when using TCP/IP.
8.17.2 Usage
Attribute type: Read and Write
This attribute is used together with ASC to build complete connection parameters
when using TCP/IP to connect to the Axell Element Manager.
Attribute configures what port number on the Axell Element Manager should be
connected to.
Format on getting parameter:
GET PPO
Reply:
<Port>
where <Port> is the port number that Axell Element Manager on IP address as
defined by attribute ASC is listening on. Valid <Port> values are 1-65 535.
Example:
GET PPO
Reply:
23
meaning that controller will attempt to connect on port 23 on the Axell Element
Manager when delivering alarms and reports.
Example:
SET PPO 4711
changes this port number to 4711.
8.18 ROP – Repeater to OMC password
8.18.1 Overview
This configures what password the controller should use when logging in to the
OMC.
8.18.2 Usage
Attribute type: Write-Only
When the controller is configured for data call, and alarms or reports are to be
transmitted to the repeater OMC / Axell Element Manager, the controller needs to
supply a user name and password. The user name is the equipment ID (attribute
RID), and the password is set with this attribute, ROP.
Format:
<Password>
Common Commands and Attributes 47/123