Document Name: Common Commands and Attributes v1.3.0 Revision: 1.2
modifies the modem initialization string.
Note 1! Modem string must NOT contain any white space (blanks).
Note 2! If logged in remotely, the changes will not take effect until the user logs
out from the controller. As soon as the user logs out and disconnects, the
initialization of the modem will be initiated.
8.12 MPE – Automatic Power Cycling Enabled
8.12.1 Overview
By configuring this, the modem can be automatically power cycled once per day.
8.12.2 Usage
Attribute type: Read and Write
The controller can be configured to automatically turn off and turn on the modem
once per day. This feature can be used to ensure that the modem parameters when
using for example GSM modems contain the latest network parameters such as HLR
update interval etc. This attribute configures whether automatic power cycling
should be enabled or not.
Format:
<Enabled>
<Enabled> = 1 means modem power cycling is enabled
<Enablde> = 0 means modem power cycling is disabled
Example:
GET MPE
Reply:
1
means that the modem power cycling is enabled.
Example:
SET MPE 0
disables the automatic modem power cycling.
Timepoint for when to power cycling the modem can be set with attribute MPT. In
order to read out modem Power Cycling timepoint, use attribute LPC. In order to
perform an instant modem power cycling, please refer to attribute ACT RCD.
8.13 MPT – Automatic Power Cycling Timepoint
8.13.1 Overview
Configures at what time of the day automatic modem power cycling should be
performed.
8.13.2 Usage
Attribute type: Read and Write
Common Commands and Attributes 44/123