Document Name: Common Commands and Attributes v1.3.0 Revision: 1.2
This action clears all alarms from the alarm log, and requires Read and Write access
when logged in. Via SMS, this can only be performed by the Main Address.
7.20 ACT TRE – Test relay
7.20.1 Overview
This action initiates a procedure to test the relay circuit.
7.20.2 Usage
Attribute type: Write-Only Action
For installation testing purposes, it is possible to test the open / close function of
the relay. This test procedure makes sure the relay is closed for a configurable
number of seconds seconds, then opens for a configurable number of seconds, and
finally closes for configurable seconds before going back to original state. Please
refer to attribbutes RTF and RTN for configuratio details.
This action requires Read and Write access when logged in. Via SMS, this can only
be performed by the Main Address.
Example:
ACT TRE
will initiate a relay circuit test, where default values are OFF for 3 seconds, ON for
10 seconds and finally OFF for 3 seconds again.
Note! During this test interval, the relay connection will be unaffected by all
alarms.
7.21 LOGDUMP ALARM
7.21.1 Overview
This command generates a list of alarms.
7.21.2 Usage
By using the command LOGDUMP ALARM, it is possible to read out alarms from the
alarm logs. The format of each line is the same as read out using the LIT attribute.
Format:
LOGDUMP ALARM <Start> <Stop>
where
<Start> is the first entry that should be read from the log, <Start> must be
greater than 0.
<Stop> is the last entry that should be read from the log, and must be greater
than or equal to <Start>.
Example:
LOGDUMP ALARM 15 20
Reply:
Common Commands and Attributes 36/123