User Manual

Table Of Contents
Document Name: Common Commands and Attributes v1.3.0 Revision: 1.2
SET RPL 1
configures the controller to open the relay circuit in case a failure is detected.
SET RPL 0
configures the controller to close the relay circuit in case a failure is detected.
7.16 RTN – Relay Test On Interval
7.16.1 Overview
This parameter is used for special test purposes and configures the On time during
relay testing.
7.16.2 Usage
Attribute type: Read and Write
In order to test the external relay output it is possible to force a test procedure,
causing the relay to be turned off for a while, then turned on and finally turned off
again during a configured interval before going back to the original state. This
attribute configures number of seconds the relay should be in ON-state during the
test phase.
Format:
<On-time>
where <On-time> is the number of seconds in on state.
Example:
GET RTN
Reply:
10
means that the relay is in on state for 10 seconds.
Example:
SET RTN 5
changes this value to 5 seconds.
7.17 RTF – Relay Test Off Interval
7.17.1 Overview
This parameter is used for special test purposes and configures the Off time during
relay testing.
7.17.2 Usage
Attribute type: Read and Write
In order to test the external relay output it is possible to force a test procedure,
causing the relay to be turned off for a while, then turned on and finally turned off
again during a configured interval before going back to the original state. This
attribute configures number of seconds the relay should be in OFF-state during the
Common Commands and Attributes 34/123