Document Name: Common Commands and Attributes v1.3.0 Revision: 1.2
Example:
GET RCA
Reply:
10
meaning that the interval between retransmissions is 10 minutes.
Example:
SET RCA 12
sets the interval to 12 minutes
7.14 RLY – Relay Status
7.14.1 Overview
This attribute can be used to readout what system status the relay reflects.
7.14.2 Usage
Attribute type: Read only
By reading this attribute, the system status as reported according to relay
configurations can be read out.
Format:
<Status>
<Status> is 0 or 1
0 means no alarms configured to activate relay is detected.
1 means that ne or more of the alarms configured to activate the relay is detected.
Please refer to attribute attribute RPL for details on configuration of relay polarity
(active open or active closed).
7.15 RPL - Relay Polarity
7.15.1 Overview
This attribute configures whether one or more error conditions in the system should
open or close the relay circuitry.
7.15.2 Usage
Attribute type: Read and Write
This attribute is used to configure how the relay circuitry should treat an error
condition.
Format:
N
N is 0 or 1
0 means that a detected error closes the relay circuit (relay is active closed)
1 means that a detected error opens the relay circuit (relay is active open)
Example:
Common Commands and Attributes 33/123