User Manual

Table Of Contents
Document Name: Common Commands and Attributes v1.3.0 Revision: 1.2
DOO.
7.3.2 Usage
Attribute type: Read only
This is a compact message of the alarm configuration strings. This attribute replies
with the configuration of the alarm sources EX1, EX2, EX3, EX4 and DOO.
The use of the attribute is mainly to increase the speed of repeater installations into
the Axell Element Manager and to present parameters in the Repeater Maintenance
Console.
Example:
GET AL1
Replies:
2 0 4 0 0 3 2 0 4 0 0 3 2 0 4 0 0 3 2 0 4 0 0 3 2 0 4 0 0 3 10 2 0 1 -30 60 3
which are the alarm configuration strings received as if using the commands
GET ALA EX1
GET ALA EX2
GET ALA EX3
GET ALA EX4
GET ALA DOO
GET ALA TEM
For a detailed description of the different alarm attributes and alarm strings, please
refer to attribute ALA.
7.4 AL2 - Compressed Alarm Format
7.4.1 Overview
A compact message retrieving alarm configurations for VLI, LGO, CLR, FWU, FWF
and RXQ.
7.4.2 Usage
Attribute type: Read only
Same as attribute AL1, but replies with configuration for alarm sources VLI, LGO,
CLR, FWU, FWF and RXQ.
7.5 AL3 - Compressed Alarm Format
7.5.1 Overview
A compact message retrieving alarm configurations for UAD, UDE, UPM, UDM and
UPW.
Common Commands and Attributes 24/123